CBWGX - ACETIC ACID AMMONIUM SALT, AX1220

  • MSDS: CBWGX
  • Manufacturer: EM SCIENCE
  • Product Name: ACETIC ACID AMMONIUM SALT, AX1220
  • National Stock Number: 6810-00N066791
Product Identification

Product ID:ACETIC ACID AMMONIUM SALT, AX1220
MSDS Date:08/04/1993
FSC:6810
NIIN:00N066791
MSDS Number: CBWGX

Responsible Party
EM SCIENCE
480 DEMOCRAT RD
GIBBSTOWN, NJ 08027
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 609-354-9200

Cage: DO242

Contractor
EM SCIENCE
70 GIBBSTOWN, NJ 08927 US

Telephone: 800-424-9300 (CHEMTREC)

Cage: DO242

Ingredients

ACETIC ACID, AMMONIUM SALT; (AMMONIUM ACETATE) (CERCLA)

CAS: 631-61-8

RTECS: AF3675000

Fraction By Weight: 100%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY BE IRRITATING ON CONTACT W/SKIN,
EYES OR MUCOUS MEMBRANES. INGESTION OF LARGE AMOUNTS CAN CAUSE
NAUSEA, DIARRHEA & SYSTEMIC AMMONIA POISONING.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:DATA NOT AVAILABLE.

First Aid

First Aid:GET MED ASSISTANCE FOR ALL CASES OF OVEREXPOSURE. SKIN:WASH
THORO W/SOAP & WATER. EYES:IMMEDIATELY FLUSH THORO W/WATER FOR AT
LEAST 15 MINUTES. INHAL:REMOVE TO FRESH AIR; GIVE ARTF RESP IF
BREATHING H AS STOPPED. INGEST:IF CONSCIOUS, DRINK WATER & INDUCE
VOMITING IMMED AS DIRECTED BY MED PERSONNEL. NEVER GIVE ANYTHING BY
MOUTH TO AN UNCONSCIOUS PERSON.

Fire Fighting

Extinguishing Media:USE ANY SUITABLE FOR ADJACENT MATERIAL.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCES TOXIC
FUMES.

Accidental Release

Spill Release Procedures:EVACUATE AREA OF ALL UNNEC PERS. WEAR SUITABLE
PROT EQUIP LISTED UNDER EXPOS/PERSONAL PROT. ELIM ANY IGNIT SOURCES
UNTIL AREA IS DETERMINED TO BE FREE FROM EXPLO OF FIRE HAZS.
CONTAIN RELS & ELIM ITS SOURCE, IF THIS CAN BE DONE W/OUT
RISK.(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED. STORE IN A COOL
AREA AWAY FROM IGNITION SOURCES & OXIDIZERS. DO NOT BREATHE DUST.
DO NOT GET IN EYES, ON SKIN OR ON CLOTHING.
Other Precautions:DO NOT TAKE INTERNALLY. MAY BE IRRITATING TO SKIN,
EYES & MUCOUS MEMBRANES. TENDS TO LOSE NH*3. DELIQUESCENT.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN .
Ventilation:MATERIAL SHOULD BE HANDLED OR TRANSFERRED IN AN APPROVED
FUME HOOD OR W/ADEQUATE VENTILATION.
Protective Gloves:NEOPRENE OR EQUIVALENT GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
SPILL PROC:TAKE UP & CONTAINERIZE FOR PROPER DISPOSAL AS DESCRIBED
UNDER DISPOSAL. COMPLY W/FEDERAL, STATE & LOCAL REGULATIONS ON
REPORTING RELEASES. REFER TO REGULATORY INFO FOR REPORTABLE QTY &
OTHE R REGULATORY DATA.

Chemical Properties

Melt/Freeze Pt:M.P/F.P Text:237F,114C
Spec Gravity:1.07 (H*2O=1)
Solubility in Water:SOLUBLE
Appearance and Odor:COLORLESS, DELIQUESCENT.

Stability

Stability Indicator/Materials to Avoid:YES
ACIDS, BASES, OXIDIZERS.
Stability Condition to Avoid:EXTREME HEAT.
Hazardous Decomposition Products:NO*X, NH*3, ACETIC ACID VAPORS.

Disposal

Waste Disposal Methods:MATL DOES NOT HAVE AN EPA WASTE NUMBER & IS NOT
A LISTED WASTE, HOWEVER CONSULTATION W/PERMITTED WASTE DISPOSAL
SITE (TSD) SHOULD BE ACCOMPLISHED. ALWAYS CONT PERMITTED WASTE
DISPOSER (TSD) TO ASSURE COMPLIANCE W/ALL CURRENT LOC, STATE & FED
REGS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.